DEPRECATED: not supported upstream This port expired on: 2025-01-31 IGNORE: You must download PowerChute Network Shutdown for Linux from https://www.apc.com/us/en/product-range/61933-powerchute-network-shutdown/, extract the archive, place Linux_x64/pcns440.tar.gz in /usr/ports/distfiles, and then run make again
PowerChute Network Shutdown (PowerChute) works in conjunction with the UPS
Network Management Card (NMC) to provide network-based shutdown of multiple
computer systems.
In the case of a UPS critical event, the software performs a graceful,
unattended system shutdown before the UPS battery is exhausted. The number of
protected systems is limited only by the capacity of the UPS.
Mk/**java.mk: Convert bsd.java.mk to USES
The following features have been added or changed:
- Instead of USE_JAVA use USES=java. This defaults to
USES=java:build,run if NO_BUILD is undefined. Else it defaults to
USES=java:run
- Instead of USE_ANT=yes use USES=java:ant which also implies
USES=java:build
- Instead of JAVA_BUILD=yes use USES=java:build. Does not imply run or
extract
- Instead of JAVA_EXTRACT=yes use USES=java:extract does not imply
build or run
- Instead of JAVA_RUN=yes use USES=java:run does not imply extract or
build
- Instead of USE_JAVA=<version> use USES=java and JAVA_VERSION=<version>
Approved by: mat (portmgr), glewis
Differential Revision: https://reviews.freebsd.org/D48201
sysutils/pcns: Set expiration date
APC had begun bundling Linux .so's for license management. This port can
no longer be used on FreeBSD without significant heroics.
Suggest taking a look at APCUPSD using the pcnet driver.
PR: 273083
Approved by: submitter is maintainer